Load shedding is why many South African households want their fridge and freezer on backup power. This calculator works out the inverter that can start and run the compressors and the battery that stores enough energy for the hours you choose, for lithium or lead acid batteries at 12, 24 or 48 volts.
TL-05How the sizes are worked out
Two numbers matter: the inverter, which must deliver the power, and the battery, which must store the energy.
- The inverter has to carry every compressor running at once, with a margin of a quarter, and the start-up surge. A compressor draws several times its running power for a moment when it starts: the calculator allows four times for the biggest one. Most inverters handle about twice their rating for a few seconds, so the size it suggests covers that.
- The battery has to hold the energy for the hours you choose. A fridge's compressor runs on and off, so the calculator uses its energy label figure plus a fifth for real kitchens, spreads it over the hours, adds about 10% for the inverter's losses and a small idle draw, and then divides by how much of the battery you can safely use: about 90% for lithium iron phosphate and about 50% for lead acid.
Typical fridge and freezer power
Typical running power, start-up surge and daily energy for new appliances. Your rating plate gives the real running power.
| Appliance | Running | Start-up surge | Energy a day |
|---|---|---|---|
| Bar fridge (about 90 L) | 70 W | about 280 W | 0.36 kWh |
| Fridge freezer (about 200 to 300 L) | 100 W | about 400 W | 0.82 kWh |
| Large fridge freezer (about 300 to 450 L) | 120 W | about 480 W | 0.99 kWh |
| Side by side or French door (500 L or more) | 180 W | about 720 W | 1.48 kWh |
| Upright freezer (about 160 to 250 L) | 100 W | about 400 W | 0.85 kWh |
| Chest freezer (about 200 L) | 90 W | about 360 W | 0.76 kWh |
Getting backup power right
- Pure sine wave only. Compressors and fridge control boards need a clean supply.
- Allow for the restart. When the grid power comes back, a good inverter switches over smoothly; a fridge that is switched off and on quickly may struggle to start against pressure in the pipes. Many fridges have a built-in delay; a time-delay plug adds one.
- A gas or petrol generator works too, but needs to be sized for the same surge and run outside.
- Have it installed properly. A fixed inverter wired into the distribution board must be installed by a registered electrician with a certificate of compliance.